Interface Studio — Prototype
Interface Studio / Axept
Prototype — nothing is saved
Project

Marti Konzern

Abacus ERP group tenant · 9 systems in scope · integration through MIP

9Systems
26Interfaces
6Direct route
20Through MIP
176Open questions
1Decision drift

Systems

Route · Interfaces
System · S02

Simma CMS

Construction site management · vendor product, reused across projects

Interfaces

Direction · Access · State

Reusable knowledge

Global catalogue

Simma CMS is the same vendor product at every customer, so its field structure carries across projects. Abacus-side mappings do not carry as reliably.

1Projects using this system
33Target fields known
6Approved Abacus mappings
Interface · S02.1 · Simma CMS

Debitorenstamm

Der Debitorenstamm aus Abacus wird über die AXsuite an die MIP übergeben und von dort ins Simma CMS verteilt.

Route

OUT Abacus provides
SourceAbacusODBC: debi.dst / publ.adr
→ODBC
IntegrationAXsuiteno data structure
→
IntermediateMIPContract ends here
→
ConsumerSimma CMScontext only

Properties

Zeit
einmal täglich (Abend zu Randzeiten)
Befehle
CREATE / UPDATE (Kein Delete)
Access method
ODBC drives field namespace & column headers
Abacus Endpunkt
ODBC: debi.dst / publ.adr
Contract holder
MIP — Marti's data warehouse layer

Field mapping

6 rows · 3 unanswered
Abacus MIP (danach via MIP ins Simma CMS) Simma CMS
Feld (ODBC)Abacus-FeldTypLängeDez.Bemerkung / Logik FeldTypLängeZwingend FeldTypLängeZwingend
DST.RecnumRecnumNumber180 RecordNumber? —
DST.DNRKundennummerNumber120 CustomerNumber contactno?String20X
DST.INRAdressnummerNumber100 Kundennummer immer gleich Adressnummer im Abacus AddressNumber? —
ADR.NAMENameString100 Name nameString100X
DST.AIDKurznameString16 ShortName matchcode✓String10
BerechnetAktivBoolean Aktiv-/Inaktiv-Status aus DST.INAKTIV ableiten Status lookcode✓Int32/Enum0X
Row 6 has no Abacus source field — it is derived. The literal Berechnet is kept exactly as written, and the derivation is recorded as a transformation rather than invented as a field.
Interface · S02.3 · Simma CMS

Debitoren Buchungen

Die bestehende manuelle Exportlösung wird durch eine ereignisbasierte Schnittstelle ersetzt.

Route

IN Abacus ingests
SourceSimma CMSPOST an AXsuite API
→REST
IntegrationAXsuiteno data structure
→
TargetAbacusContract ends here

No MIP stage. The same model expresses both directions — nothing here is a special case.

Properties

Decision drift
Zeit
Eventbasiert ("Real-Time")
Befehle
CREATE (Kein "UPDATE" oder "DELETE") von Belegen
Access method
REST Entity API column header becomes "Abacus REST Feld Bezeichnung"
Abacus Endpunkt
https://apihub.abacus.ch/apis/2026/entity/customerinvoices
Response
HTTP 200 + ForeignID · bei Fehler HTTP-Statuscode + Abacus Fehlermeldung
Decision drift — DevOps #36642 The workbook cell reads “Es wird eine eigene Belegart für die Simma Belege im Abacus vorgesehen.” The authoritative DevOps Entscheidung reads “…für die Simma sowie IQ-Steel Belege…”. DevOps wins; the workbook copy is stale.
System · S01

Cognos

Reporting · files prepared manually, outside AXsuite and MIP

Route

Direct
SourceAbacusaccess method not chosen
→
Manual actorFile exportprepared by a user
→
ConsumerCognosContract ends here

S01.1 Fibu Kontosaldi

Workshop completeAbacus mapping pending
Abacus Cognos
FeldTypBemerkung / Logik FeldTypBemerkung
—Stichtag aus ProzessinputStichtagDatum
—Leitwährung von GBWährungString
2. KontennummerNumberKontonummerNumber
—Total pro Cognos-KontoSaldoDecimal
Not an error

The workshop collected what Cognos needs. The Abacus side is still empty because nobody has mapped it yet — that is the normal state between the workshop and the mapping session, so no validation warning is raised.

Marti Konzern

New interface

One interface is one dataset. Start from what the counterparty needs; map to Abacus later.

Identifier S02.1 is assigned automatically.

The access method selects which Abacus field namespace the pickers use, and which column headers the exported workbook carries. It can be left undecided.

Export

Marti Konzern Schnittstellenspezifikation S02 Simma CMS

Generated workbook — German throughout, because it goes to the customer for review.

SchnittstelleS02.01 Debitorenstamm
BeschreibungDer Debitorenstamm aus Abacus wird über die AXsuite an die MIP übergeben.
Zeiteinmal täglich (Abend zu Randzeiten)
BefehleCREATE / UPDATE (Kein Delete)
Abacus EndpunktODBC: debi.dst / publ.adr
Abacus MIP (danach via MIP ins Simma CMS) Simma CMS
Feld (ODBC)Abacus-FeldBemerkung / Logik / Mapping FeldBemerkung Feld
DST.RecnumRecnumRecordNumber@Marti: Wird dieses Feld benötigt? · @Axept: Kann gestrichen werden.
DST.DNRKundennummerCustomerNumber@Axept: Suchbegriff max. 10 Zeichencontactno
DST.INRAdressnummerKundennummer = AdressnummerAddressNumber@Marti: bestätigen
ADR.NAMENameNamename
DST.AIDKurznameShortNamematchcode
BerechnetAktivaus DST.INAKTIV ableitenStatuslookcode
Abacus source MIP intermediate Consumer Bemerkung

Fidelity check

6 of 6 rows match

The generated workbook is diffed cell by cell against the hand-made file. It passes only when every difference can be named.

142Cells compared
139Identical
3Deliberate change
0Unexplained
System

System

Not built out in this prototype. The three worked examples are Simma CMS (S02), Cognos (S01) and the new-interface flow.